WAIT - Read the Required Files section before downloading this file.

Unless stated otherwise, the file listed below must be installed BEFORE the ILCE-7RM4 System Software (Firmware) Update Ver.1.20 (Mac) in order for it to work properly. If more than one Required file is listed, install them in the order presented on this page.

Applicable Models

This information is for the following models:

  • ILCE-7RM4

About this download

Benefits and Improvements

  • Adds support for the LA-EA5 A-Mount Adapter (sold separately) (Added on 03-09-2020)
    • LA-EA5 A-Mount Adapter supports all A-mount lenses
    • Full support is provided for focal plane phase-detection AF, and the AF and high-speed continuous shooting features
    • Wide-area focal plane phase-detection AF coverage
    • AF features based on subject recognition, including Real-time Eye AF (human, animal) and Real-time Tracking
    • AF/AE tracking during continuous shooting at up to 11fps
    Notes:
    • STF lenses are manual focus only
    • Teleconverters are not supported for use with any A-Mount Adapters
    • Autofocus is not available during movie recording when using the LA-EA5 A-Mount Adapter
    • For AE tracking, the aperture is fixed for the first frame while shutter speed and ISO are used for exposure adjustment
    Please refer to the HelpGuide for updated function usage.
  • The Auto Focus (AF) performance is improved when recording movies with the FE 12-24mm F2.8 GM (SEL1224GM) lens
  • Improves the overall stability of the camera

Previous Benefits and Improvements

The following benefits and improvements are also included in this update.

  • Enables use of "My Menu" to save or load custom camera settings
  • Adds the "External Flash Set" function:
    This function allows you to configure the settings of an attached flash or wireless radio commander (both sold separately) directly from the camera.
    Compatible Flash models
    • HVL-F60RM (with flash firmware version 2.00 or later)
    • HVL-F45RM (with flash firmware version 2.00 or later)
    Compatible wireless radio commander:
    • FA-WRC1M (with firmware version 3.00 or later)

    Please refer to the Help Guide for more information:

  • Improves the overall stability of the camera

File Info

File Name

  • ILCE-7RM4 System Software (Firmware) Update Ver.1.20 (Mac)

File Version

  • 1.20

File Size

  • 350.7 MB (350,744,636 bytes)

Release Date

  • 06-08-2020

Preparation

Check the system software version

Follow the instructions below to check the system software version. If the system software version is Ver.1.20, the update is not required.

  1. Select Menu → Setup subpage [6] → Version on the camera.
  2. The system software version is displayed as illustrated below.
    System Software Version

System Requirements

Operating Systems

The latest version of the system software update is compatible with the following Macintosh versions:

  • macOS 10.13 – 10.15

    IMPORTANT:
    For macOS 11 – 12, please ensure the "System Software Update Helper" has been installed before update your software.

Computer Hardware

The latest version of the system software update is compatible with the following hardware:

  • Hard drive space: 600 MB or more
  • RAM: 512 MB or more

Other Hardware

  • Power source for the device.
    Fully charged rechargeable battery pack NP-FZ100.
    Note: The update can only be performed when the battery power level is Battery Power Level (three bars) or more. We recommend that you use a fully charged battery. Detach the vertical grip before updating system software.
  • USB cable supplied with the device
    Note: Update functionality is not guaranteed with any other USB cable.

Important notice

  • Please close all other application software before updating the system software.
  • Use a fully charged rechargeable battery pack (NP-FZ100).
  • Do not remove the battery during the update; as the sudden loss of power may render the camera inoperable.
  • Remove the memory card from the camera before starting the update process.
  • The system software update will take approximately 15 minutes. Please do not allow your computer to go into Sleep mode during this time.
    If the computer does go into Sleep mode and the update is interrupted, the entire update process will need to be restarted.
  • Do not open "About This System Software Updater" in the System Software Updater menu as this may cause the Updater software to crash.
  • Do not connect the camera to any other devices except your computer.
  • Do not connect the camera and computer yet.

How to download the Updater:

  1. After reading the disclaimer, click Download.
  2. The [Update_ILCE7RM4V120.dmg] file will start downloading.
  3. Save the file to the desktop of your computer (recommended).

Step 1: Start the Updater

  1. Close all currently programs currently running on your computer.
  2. Double-click the [Update_ILCE7RM4V120.dmg] file you downloaded. Do not connect the camera at this point.
    Note: If you have connected the camera to a computer, disconnect it before following the procedure.
  3. [Update_ILCE7RM4V120] is expanded.
  4. Double-click the [UpdateSetting Tool] icon. UpdateSetting Tool
  5. To load a kernel extension, the message prompts you to allow the application to make changes. Type the password for the administrative account.
    Enter the User Name and Password

    Once the message from the system displays, the security and privacy screen will be displayed.
    • If the following message is displayed before "Security and Privacy" is displayed, press the [OK] button.
      Press the OK Button
    • Open the "General" tab on the "Security and Privacy" screen and allow reading of the "Sony Corporation" system software.
      Security and Privacy screen
      Note: If you have approved this in the past, the security and privacy screen will not be displayed.
    • If you are asked to restart macOS after clicking the [Allow] button, please restart and return to the beginning of the update procedure.
    • If the "Security and Privacy" screens does not disappear, please close the window.
    • If both the message displayed and the "Security and Privacy" screen do not disappear, close both using the [OK] button.
      System Extension Blocked screen
  6. Connect the camera to the computer.
    • A dialogue box for the USB connection will be displayed.
      Connect the device to the computer with the USB cable
    • Connect the camera to the PC using the USB cable (supplied). "USB Mode" appears on the LCD monitor of the camera.
      Note: If the USB cable was connected before the dialog box prompting USB connection appeared, disconnect the USB cable and start again from "Step 1. Start the Updater".
    • Click [OK]. If the message is displayed, close using the [OK] button.
      Press the OK Button
      Note: Never turn off the camera nor disconnect the USB cable while updating.
  7. The System Software Updater will start.
    System Software Updater
    Note: If the System Software Updater does not start up, double-click [System Software Updater] in the [Update_ILCE7RM4V120] - [Resources] folder to start up.
  8. Turn on the camera.
  9. Following the instructions in the System Software Updater window, on the camera, select Menu → Setup subpage [4] → USB Connection and check if Mass Storage has been selected. If a mode other than Mass Storage is selected, please select Mass Storage.
    Setup[4] - Mass Storage
  10. Connect the camera to the computer with the supplied USB cable. "USB Mode" appears on the LCD screen of the camera.
    Note: If the computer cannot find the device, the message "Could not find the camera for this update" is displayed on the computer screen. Please try the following:
    • Disconnect the USB cable and connect it again.
    • If the computer has multiple USB terminals, try with the other terminals.

    Sometimes, when the camera is connected to the computer with the USB cable, a message prompting you to restart the computer may be displayed.
    If this happens, remove the battery pack from the camera, reboot the computer and follow the instructions from "Step 1: Start the Updater".
  11. Click [Next]. The current version number and updated version number appear on the lower left-hand side of the screen.After confirming that the current software version is "Ver. 1.10 or earlier", click Next. If the current system software version is 1.20 or later, the update is not required.In this case, disconnect the camera from the computer and click Finish. Turn off the camera, remove the battery pack, reinsert the battery and turn the camera back on.

    Update is required
    Current Version and Updated Version Numbers

    Update is not required
    Update is not required
  12. The camera will automatically be reset.
    The screen below will be displayed.
    The camera is automatically reset
    Note: The Loading icon may not be displayed depending on the OS version that you are using.
  13. Start the update.
    After automatically resetting, the following screen is shown and the update starts. The progress bar appears during the update process (approximately 15 minutes).
    Note: Never turn off the camera or disconnect the USB cable while updating.
    Update Progress Bar
  14. Complete the update.
    Once the update has been completed, the camera will automatically restart. Make sure that the camera is turned on and wait until the LCD screen appears again. Click Finish when the LCD screen appears and disconnect the USB cable.
    Click Finish
    Note: After restarting, a data recovery warning is sometimes displayed. This is normal. Please wait until this warning disappears.
    Recovering data. Please wait...

Step 2: Confirm the system software version of your device.

  1. On the camera, select Menu → Setup subpage [6] → Version
  2. The system software version is displayed as illustrated below.
    Updated System Software Version

Questions & Answers

The update does not complete

When the monitor remains black for more than 15 minutes, follow these steps to troubleshoot the issue:

  1. Disconnect the USB cable from the computer.
  2. Remove the battery and AC adapter from the camera, leave it for a few minutes, then insert the battery again or connect the AC adapter.
  3. Restart the computer.
  4. Turn on the camera and perform the installation process again.